1、安科瑞限流式保護(hù)器 單相智能短路滅弧器 概述
ASCP200-1型電氣防火限流式保護(hù)器可克服傳統(tǒng)斷路器、空氣開(kāi)關(guān)和監(jiān)控設(shè)備存在的短路電流大、切斷短路電流時(shí)間長(zhǎng)、短路時(shí)產(chǎn)生的電弧火花大,以及使用壽命短等弊端,當(dāng)發(fā)生短路故障時(shí),能以微秒級(jí)速度快速限制短路電流以實(shí)現(xiàn)滅弧保護(hù),從而能顯著減少電氣火災(zāi)事故,保障使用場(chǎng)所人員和財(cái)產(chǎn)的。
ASCP200-1型電氣防火限流式保護(hù)器是單相限流式保護(hù)器,大額定電流為63A??蓮V泛應(yīng)用于學(xué)校、醫(yī)院、商場(chǎng)、賓館、休閑場(chǎng)所、寺廟、會(huì)展、住宅、倉(cāng)庫(kù)、電動(dòng)車充電站及工廠等各種用電場(chǎng)所末端干、支路的線路保護(hù)。
2、安科瑞限流式保護(hù)器 單相智能短路滅弧器 功能特點(diǎn)
■ 短路保護(hù)功能。保護(hù)器實(shí)時(shí)監(jiān)測(cè)用電線路電流,當(dāng)線路發(fā)生短路故障時(shí),能在150微秒內(nèi)實(shí)現(xiàn)快速限流保護(hù),并發(fā)出聲光報(bào)警信號(hào)。
■ 過(guò)載保護(hù)功能。當(dāng)被保護(hù)線路的電流過(guò)載且過(guò)載持續(xù)時(shí)間超過(guò)動(dòng)作時(shí)間(3…60秒可設(shè))時(shí),保護(hù)器啟動(dòng)限流保護(hù),并發(fā)出聲光報(bào)警信號(hào)。
■ 表內(nèi)超溫保護(hù)功能。當(dāng)保護(hù)器內(nèi)部器件工作溫度過(guò)高時(shí),保護(hù)器啟動(dòng)超溫限流保護(hù),并發(fā)出聲光報(bào)警信號(hào)。
■ 過(guò)、欠壓保護(hù)功能。當(dāng)保護(hù)器檢測(cè)到線路電壓過(guò)壓或欠壓時(shí),保護(hù)器發(fā)出聲光報(bào)警信號(hào),可預(yù)先設(shè)置是否啟動(dòng)限流保護(hù)。
■ 配電線纜溫度監(jiān)測(cè)功能。當(dāng)被監(jiān)測(cè)線纜溫度超過(guò)報(bào)警設(shè)定值時(shí),保護(hù)器發(fā)出聲光報(bào)警信號(hào),可預(yù)先設(shè)置是否啟動(dòng)限流保護(hù)。
■ 漏電流監(jiān)測(cè)功能。當(dāng)被監(jiān)測(cè)的線路漏電超過(guò)報(bào)警設(shè)定值時(shí),保護(hù)器發(fā)出聲光報(bào)警信號(hào),可預(yù)先設(shè)置是否啟動(dòng)限流保護(hù)。
■ 保護(hù)器具有1路RS485接口,1路2G無(wú)線通訊,可以將數(shù)據(jù)發(fā)送到后臺(tái)監(jiān)控系統(tǒng),實(shí)現(xiàn)遠(yuǎn)程監(jiān)控。監(jiān)控后臺(tái)可以是安科瑞Acrel-6000/B電氣火災(zāi)監(jiān)控主機(jī),也可以是安科瑞Acrel-6000云平臺(tái),或第三方監(jiān)控軟件或平臺(tái)。
3、技術(shù)指標(biāo)
4、外形及安裝尺寸
5、產(chǎn)品應(yīng)用
應(yīng)用接線圖
注意事項(xiàng):
1)在選用限流式保護(hù)器時(shí),限流式保護(hù)器的設(shè)定的額定電流應(yīng)該與其前一級(jí)的斷路器的額定電流保持*。例如,當(dāng)限流式保護(hù)器輸入端斷路器的額定電流為32A時(shí),應(yīng)將限流式保護(hù)器的額定電流設(shè)置為32A。為保障限流式保護(hù)器的正常使用,嚴(yán)禁將其使用于與其前端斷路器的額定電流不匹配的配電線路中。
2)ASCP200系列采用限流式保護(hù)器采用壁掛式安裝,可以掛墻安裝,也可以安裝在箱體內(nèi),應(yīng)確保安裝場(chǎng)所無(wú)滴水、腐蝕性化學(xué)氣體和沉淀物質(zhì),并注意環(huán)境溫度和通風(fēng)散熱。
3)為確??煽窟B接,接線時(shí)應(yīng)按接線圖進(jìn)行,同時(shí)為了防止接頭處接觸電阻過(guò)大而導(dǎo)致局部過(guò)熱,也避免因接觸不良而導(dǎo)致保護(hù)器工作不正常,線頭應(yīng)采用合適大小的U形冷壓頭壓接后,再插入保護(hù)器相應(yīng)端子上并將螺釘擰緊壓實(shí)。
4)保護(hù)器內(nèi)部帶有交流電,嚴(yán)禁非人士擅自打開(kāi)產(chǎn)品外殼。保護(hù)器在使用期間,若被保護(hù)線路發(fā)生短路或過(guò)載故障而被限流保護(hù)時(shí),保護(hù)器仍處于帶電狀態(tài),不允許隨意碰觸用電線路的金屬部分。待檢查線路,并排除故障后,長(zhǎng)按保護(hù)器的復(fù)位按鍵約2秒鐘,使保護(hù)器恢復(fù)正常運(yùn)行時(shí)。
5)當(dāng)保護(hù)器因超溫而發(fā)生限流保護(hù)時(shí),則可能是因?yàn)樨?fù)載電流過(guò)大,環(huán)境溫度過(guò)高或通風(fēng)散熱不良等原因?qū)е?,可通過(guò)加強(qiáng)通風(fēng)等措施,等保護(hù)器溫度降下來(lái)后,再長(zhǎng)按復(fù)位鍵,使保護(hù)器復(fù)位,恢復(fù)正常運(yùn)行。
1) When selecting a current-limiting protector, the rated current of the current-limiting protector should be maintained with the rated current of the circuit breaker of its predecessor*. For example, when the current limit protector input circuit breaker is rated at 32A, the current rating of the current limit protector should be set to 32A. In order to ensure the normal use of the current limit protector, it is strictly forbidden to use it in the distribution line that does not match the rated current of its front-end circuit breaker.
2) ASCP200 series using flow-limiting protector using wall mounting, can be hung wall installation, can also be installed in the box, should ensure that the installation site is free of dripping, corrosive chemical gases and precipitated substances, and pay attention to ambient temperature and ventilation and heat dissipation.
3) In order to ensure reliable connection, the wiring should be carried out according to the wiring diagram, and in order to prevent the contact resistance at the joint from being too large and causing local overheating, and also to avoid the improper operation of the protector due to poor contact, the wire head should be pressed with a U-shaped cold indenter of the appropriate size, and then inserted into the corresponding terminal of the protector and tighten the screw compaction.
4) The protector has ALTERNA inside, and it is strictly forbidden for non-persons to open the product shell without authorization. During the use of the protector, if the protected line is short-circuited or overloaded and protected by current limiting, the protector is still in a live state, and it is not allowed to touch the metal part of the power line at will. After checking the line and troubleshooting, press and hold the reset button of the protector for about 2 seconds to restore the protector to normal operation.
5) When the protector is subject to current limit protection due to overtemperature, it may be caused by excessive load current, excessive ambient temperature or poor ventilation and heat dissipation, etc. It can be caused by strengthening ventilation and other measures, and after the temperature of the protector drops, press the reset button for a long time to reset the protector and restore normal operation.
典型應(yīng)用示意圖
6、安科瑞Acrel-6000用電云平臺(tái)
安科瑞Acrelcloud-6000用電管理平臺(tái)是針對(duì)我國(guó)當(dāng)前電氣火災(zāi)事故頻發(fā)而創(chuàng)新的一套電氣火災(zāi)預(yù)警和預(yù)防管理系統(tǒng),該系統(tǒng)是基于移動(dòng)互聯(lián)網(wǎng)、云計(jì)算技術(shù)、通過(guò)物聯(lián)網(wǎng)傳感終端(現(xiàn)場(chǎng)監(jiān)控模塊、傳輸模塊),將供電側(cè)、用電側(cè)電氣參數(shù)實(shí)時(shí)傳輸至云服務(wù)器。用電管理云平臺(tái)可以不受時(shí)間、地點(diǎn)、環(huán)境的限制,自行選擇合適的方式(本地電腦、手jiAPP、短信)來(lái)掌控用電系統(tǒng)的運(yùn)行情況,做到“早預(yù)防、快報(bào)警、自診斷、出報(bào)告”的工作流程化。
6.1平臺(tái)結(jié)構(gòu)
6.2應(yīng)用場(chǎng)所
AcrelCloud-6000用電管理云平臺(tái)的主要應(yīng)用場(chǎng)合:
大型商場(chǎng)、超市、學(xué)校、養(yǎng)老院、福利院、車站、醫(yī)院、賓館等領(lǐng)域、勞動(dòng)力密集型企業(yè)、易燃易爆倉(cāng)庫(kù)、木材加工、紡織、涉塵、噴涂、制藥等企業(yè)、酒吧、網(wǎng)吧等娛le場(chǎng)所、小餐館、門(mén)店及各種小微企業(yè)。
6.3主要功能
實(shí)時(shí)監(jiān)控
24小時(shí)監(jiān)視各探測(cè)點(diǎn)的剩余電流、溫度、電壓、電流、狀態(tài)等信息;
歷史記錄
所有告警信息及遠(yuǎn)程控制均被記錄入日志,并可供用戶方便查詢;
數(shù)據(jù)分析
針對(duì)采集的數(shù)據(jù)進(jìn)行各種模型分析,為客戶隱患;
報(bào)警提醒
當(dāng)平臺(tái)收到報(bào)警或故障信息時(shí),平臺(tái)將以各種方式推送和企業(yè)管理人員,提醒關(guān)注故障狀況,并采取相應(yīng)的措施隱患;
權(quán)限管理
給不同的操作人員分配不同的權(quán)限,從而提高系統(tǒng)整體性;
遠(yuǎn)程控制
具備權(quán)限的管理人員可以遠(yuǎn)程設(shè)定探測(cè)器的各種參數(shù)值,或者對(duì)監(jiān)控設(shè)備進(jìn)行分閘、合閘、復(fù)位等操作,方便管理,同時(shí)提高工作效率。
6.4平臺(tái)主要功能介紹
1)平臺(tái)首頁(yè)
通過(guò)平臺(tái)首頁(yè)可以快速瀏覽隱患巡查界面或隱患處理界面、本月隱患、故障統(tǒng)計(jì)以及項(xiàng)目信息地圖導(dǎo)航。
2)實(shí)時(shí)監(jiān)控
通過(guò)實(shí)時(shí)監(jiān)控界面,除了可以實(shí)時(shí)顯示項(xiàng)目所屬客戶、地址、建筑面積、消防設(shè)施、責(zé)任人、聯(lián)xi電話、設(shè)備數(shù)量、探測(cè)器數(shù)量等信息,還以更醒目的方式顯示了未處理報(bào)警和未處理故障信息,下屬設(shè)備和探測(cè)器,并可以查看各設(shè)備以及探測(cè)器基本信息、開(kāi)關(guān)操作、數(shù)據(jù)監(jiān)控、實(shí)時(shí)數(shù)據(jù)、參數(shù)設(shè)置、歷史信息和報(bào)警信息等。
3)隱患管理
隱患管理包括隱患巡查、隱患處理、和隱患記錄。