生
物液相色譜柱本公司現(xiàn)貨產(chǎn)品
MX6復(fù)合氣體檢測儀 現(xiàn)貨美國英思科M40四合一氣體檢測儀
TN3紅外測溫儀 fluke 59mini紅外測溫儀 照度計(jì) CENTER337 tx2000 h2氫氣檢測儀 HI93734-01余氯、總氯(Cl2)配套試劑 HI93735-01總硬度配套試劑
3011食品中心溫度計(jì) FD216測氡儀土壤取樣器 HGY2058在線電磁式酸堿濃度計(jì)
HGY2018在線PH計(jì) RE5299 旋轉(zhuǎn)蒸發(fā)器 AR3130電子天平 SA1200(P)空氣消毒機(jī)
YSI85-10 手提式野外水質(zhì)測量儀 DO200在線溶解氧測定儀 YSI556MPS型多參數(shù)水質(zhì)檢測儀 3M6800防毒面罩 美國華瑞PGM-2400 四合一復(fù)合式氣體檢測儀 YSI3100 電導(dǎo)率儀 HT10S煙氣黑度照相測定儀 正壓式空氣呼吸器 COD-571-1型消解裝置
PPMhtv甲醛檢測儀 AD102農(nóng)藥檢測卡 DYM3型空盒氣壓表 PROVA5637鉤式接地電阻計(jì)
PRM-3040射線檢測儀 美國MSA 10108311歐特防護(hù)眼鏡 PGM-1700 硫化氫便攜式氣體檢測儀 MIC-800-CO2便攜式二氧化碳檢測儀 MIC-500-CH4O 甲醇探測器
YSI 550A型便攜式溶氧儀 TES-1360A溫濕度計(jì) GM1357聲級計(jì)
PGM-7840復(fù)合氣體檢測儀 GDYS-102SJ尿素測定儀 GDYS-101ST鐵測定儀
GDYS-101SC2臭氧測定儀 GDYN-110SA農(nóng)藥殘毒快速檢測儀(10通道)
GDYS-101SC2臭氧測定儀 D3A激光測距儀
本月*產(chǎn)品
現(xiàn)貨美國英思科M40四合一氣體檢測儀 M40硫化氫傳感器 PGM-7840復(fù)合氣體檢測儀 PGM-6208 6合一氣體檢測儀 FGM-1100 IR 可燃?xì)庠诰€監(jiān)測儀
PRM-1200(DoseRAE 2)射線檢測儀 FGM-3300 環(huán)氧乙烷(ETO)氣體檢測儀
M40一氧化碳傳感器 M40氧氣傳感器 PGM-1600可燃?xì)怏w儀
DNASwift SAX-1S
ProPac Ion Exchange
ProPac HIC-10
ProPac IMAC-10
ProSwift
Acclaim 300 Reversed-Phase
Acclaim PepMap
Acclaim PepMap Micro and Capillary
Acclaim PepMap and TiO2 Nano Precolumns
PepSwift Monolithic Columns and Precolumns
Amino Acid Columns
Nucleic Acid Columns
Carbohydrate Columns
ProPac 離子交換色譜柱
Dionex offers four polymer-based columns for the separation of proteins by ion exchange chromatography. Each of these ultra-high efficiency columns provides sufficient resolution to allow separation of protein isoforms that, in many cases, differ by only a single amino acid residue. ProPac HIC 色譜柱
The ProPac® HIC-10 is a new silica-based HPLC column for the separation of proteins by hydrophobic interaction chromatography. These HIC columns have been developed with multifunctional ligand attachments to provide enhanced hydrolytic stability under standard HIC elution conditions. The ProPac HIC-10 columns offer exceptional resolution and provide high loading capacity, making them ideal for protein separation and purification. Proswift 整體柱 Acclaim 300 反相硅膠色譜柱,用于蛋白,多肽,和小分子物質(zhì)的分離
The Acclaim® 300 columns are a wide-pore line of C18 reversed-phase columns manufactured by Dionex for the separation of proteins, peptides, and other biological macromolecules. This line of columns extends the same unique bonding chemistry developed for the Acclaim 120 columns to a wide-pore silica substrate. The Acclaim 300 columns consist of 3-µ-diameter silica particles with 300-Å diameter pores, bonded with a highly characterized C18 phase. The unique bonding chemistry results in a high-density, highly uniform phase coverage with extensive end-capping.
ProPac IMAC 色譜柱
The ProPac IMAC-10 Column is an HPLC column for the separation, by immobilized metal affinity chromatography (IMAC), of certain proteins and peptides with an affinity for a specific group of metals. This column represents the latest advancement in IMAC technology; it is a true high pressure, high resolution column capable of separating not only metal-binding proteins from non metal binding proteins, but in many cases also providing resolution of retained metal-binding proteins from one another.
Acclaim PepMap for TFA-Free 肽譜
Acclaim® PepMap™ is a silica-based C18 stationary phase with virtually zero silanophilic activity, offering outstanding separation of peptides with minimal band broadening. As a result, TFA is no longer required in peptide mapping, allowing the use of solvent additives, such as formic acid, with substantially lower signal suppression and higher sensitivity in mass spectrometry (MS). Microcolumns packed with Acclaim PepMap are available from 75-µm i.d. up to 1.0-mm i.d. in different lengths and configurations to permit easy connection to MS.
Acclaim PepMap 微流速、毛細(xì)管預(yù)柱和分析柱
Micro and Nano Precolumns are used for preconcentration of dilute samples, in sample cleanup, or in various column-switching techniques. Dilute samples can be effectively concentrated on the micro or nano precolumn by selecting the proper packing material. Micro and nano precolumns are used for fast sample concentration in combination with large-volume injections. Column lengths of 1 mm for nano precolumns (300 µm i.d.) and of 5 or 15 mm for micro precolumns (i.d. 300, 500, 800 µm, or 1.0 mm) shorten loading time, which results in reduced overall analysis time. Desalting and multidimensional (2-D, 3-D, etc.) chromatography are other applications.
Acclaim PepMap and TiO2 Nano 預(yù)柱
Nano Precolumns are short columns (1 cm or 2 cm), with an inner diameter of 100 or 200 µm. They are used for preconcentration (focusing) of diluted samples, or in various column-switching techniques.
PepSwift 整體柱和蛋白預(yù)柱
PepSwift TM Monolithic columns for proteomics applications offer various benefits over particulate columns. The polymeric rod with porous structure, and no intra-particular void volumes, improves both mass transfer and separation efficiency, allowing for fast, high-resolution separation of proteins and peptides. 氨基酸色譜柱
Dionex offers two approaches to amino acid analysis: (1) anion-exchange separation by AAA-Direct TM in which amino acids are detected directly, without the need for derivatization, or (2) anion-exchange separation with postcolumn derivatization. The AminoPac® PA10 is the recommended column for AAA-Direct, whereas the AminoPac PA1 is used with postcolumn derivatization. 核酸分析柱
The DNAPac® series of columns are polymer-based, anion-exchange columns that set the standard for oligonucleotide purity checks, fast screenings, and purification. The DNAPac PA200 offers exceptional resolution, phase stability over a broad pH range, and the ability to perform high-throughput separations. The DNAPac PA100 columns combine high-resolution separations with scalability for DNA analyses. Specially designed protocols using the Dionex BioLC® system enable resolution on these columns of normal-length oligonucleotides (8- to 30-mer), extended-length oligonucleotides (30- to 70-mer), and with the DNAPac PA100, linear double-stranded DNA and supercoiled versus nicked/linear DNA. 糖分析柱
Whether your interest is oligosaccharide mapping, mono- and disaccharide analysis, or monitoring sugars and sugar alcohols, a CarboPac TM high-performance anion-exchange (HPAE) column can help. The CarboPac family of columns has five columns to choose from, and each is optimized for a different class of compounds. Combined with pulsed amperometric detection (PAD)—which provides a means to detect the carbohydrates without derivatization—the CarboPac columns provide you with a simple, reliable technique to separate your sugars. 生物富集柱
Dionex offers three trap columns for bio applications to reduce sample preparation and ensure your successful chromatographic separation. The BorateTrapTM removes borate from the eluent and is recommended for sugar alcohol and monosaccharide applications. The AminoTrapTM retains amino acids contaminants in carbohydrate separations. The SugarTrap removes carbohydrate contaminants from amino acid separations.