1、水池中的水長(zhǎng)時(shí)間停留在水箱當(dāng)中容易滋生各種細(xì)菌,綠藻,紅線蟲(chóng)等,從而嚴(yán)重影響人體體質(zhì),針對(duì)此情況,我公司推出石家莊ZM-1水箱消毒機(jī)器來(lái)解決此問(wèn)題。
2、本設(shè)備安裝時(shí)借助于水箱、水池入孔,無(wú)特殊情況,無(wú)需破壞水箱、水池、管路等原系統(tǒng)設(shè)施。
一、石家莊ZM-1水箱消毒機(jī)器安裝程序?yàn)椋?span lang="EN-US">
①、必須將水箱、水池清理干凈。
②、將消毒循環(huán)器(不銹鋼球)放于水箱、水池底部*即可,有多臺(tái)消毒器時(shí)應(yīng)均勻布置。
③、控制柜掛裝在墻上,它必須安裝在防雨、防水措施的干燥通風(fēng)處并且嚴(yán)禁被水濺濕。設(shè)備離地面>1.5米。(略高于水箱)
④、建議在水箱、水池的頂蓋上,消毒循環(huán)器放置上方1米半徑范圍內(nèi)預(yù)留一個(gè)直徑50mm(供消毒循環(huán)器傳輸線出線)的圓形電纜出線孔。
⑤、將消毒循環(huán)器的電纜從上述電纜出線孔引出至控制柜旁,在圓孔處將電纜固定。
⑥、將消毒循環(huán)器的電纜與控制柜接線端子相連接;將循環(huán)器接出的白色軟管與控制柜內(nèi)的軟管相連,用電工膠帶密封住接口。
⑦、將220V/50Hz電源與控制柜相連接。經(jīng)過(guò)上述操作后,本設(shè)備安裝結(jié)束。
二、 石家莊ZM-1水箱消毒機(jī)器的開(kāi)機(jī)方法:
1、向水箱或水池注水,使水位淹沒(méi)消毒器(必須淹沒(méi))。
2、打開(kāi)控制柜門,將空開(kāi)合上。此時(shí),控制柜門上的電源指示燈和工作指示燈都將點(diǎn)亮,說(shuō)明設(shè)備已開(kāi)始正常工作。
3、時(shí)間繼電器的調(diào)節(jié):左邊為開(kāi)機(jī)時(shí)間,右邊是停機(jī)時(shí)間,一般為開(kāi)停比例為1比3,如開(kāi)10分鐘停30分鐘。
三、石家莊ZM-1水箱消毒機(jī)器的停機(jī)方法:
1、 打開(kāi)控制柜的門。
2、將電源總開(kāi)關(guān)斷開(kāi)。此時(shí)電源指示燈和工作指示燈都將熄滅,說(shuō)明設(shè)備已停止工作。
Shijiazhuang WTS
1, cistern is long time stay in water tank tend to produce of all sorts of bacteria, green algae, red nematodes, thus seriously affect human body constitution, in view of this situation, I introduced shijiazhuang WTS
2, the equipment installation by pool water tank, when the hole, no special circumstances, unnecessary damage tank, and pools, pipeline, etc the original system facilities.
A,
(1), will have to clean up the water tank, and pools.
(2), disinfection cycle device (stainless steel ball) put in the tank, and pools center bottom can, how should decorate a sterilizer evenly.
(3) hang on the wall, cabinet put, it must be installed in the rain, waterproof measures of dry and ventilated place it is strictly prohibited to be the water splashed wet. Equipment from the ground > 1.5 meters. (best slightly above the water tank)
(4), Suggestions in water tank, that pool, disinfection is placed above
(5), disinfection of cable from the above the circulation cable outlet to draw out the hole control cabinet, in the round hole will cable fixed.
6, disinfection of cable and the cycle control cabinet connected terminals; Pick out the cycle of the white hose and control of the inside ark hose, with electrical tape sealing live interface.
7, 220 V/frequency 50 Hz power in connection with the control cabinet. After the operation, the equipment installation ends.
Second,
1, to the water tank or pool water injection, to bring the level submerged disinfector (must be submerged).
2, open cupboard door control, will close on empty. At this time, the indicator of the cupboard door control and work will be lit indicator that equipment has started to work properly.
3, time relay regulation: the left for boot time, on the right is the down time, generally for open stop proportion is 1 than 3, such as opening 10 minutes stop 30 minutes.
Three,
1, open the door of the cabinet.
2, will always switch power supply. At this time of the indicator lights and work will be put out, explain equipment has stopped working.