工作原理
電站熱電偶的電極由兩根不同導(dǎo)體材質(zhì)組成。當(dāng)測量端與參比端存在溫差時(shí),就會(huì)產(chǎn)生熱電勢,工作儀表便顯示出熱電勢所對應(yīng)的溫度值。熱電阻是利用物質(zhì)在溫度變化時(shí),其電阻也隨著發(fā)生變化的特征來測量溫度的。當(dāng)阻值變化時(shí),工作儀表便顯示出阻值所對應(yīng)的溫度值。
主要技術(shù)參數(shù)
產(chǎn)品執(zhí)行標(biāo)準(zhǔn):
IEC584
IEC751
IEC1515
JB/T18622-1997
JB/T8623-1997
GB/T16839-1997
測量范圍及允差
型號(hào) | 分度號(hào) | 允差等級 | |||||
Ⅰ | Ⅱ | ||||||
允差值 | 測溫范圍 °C | 允差值 | 測溫范圍 °C | ||||
WRN | K | ±1.5°C | -40~+375 | ±2.5 °C | -40~+333 | ||
±0.004ltl | 375~1000 | ±0.0075 ltl | 333~1200 | ||||
WRM | N | ±1.5°C | -40~+375 | ±2.5°C | -40~+333 | ||
±0.004 ltl | 375~1000 | ±0.0075 ltl | 333~1200 | ||||
WRE | E | ±1.5°C | -40~+375 | ±1.5°C | -40~+333 | ||
±0.004 ltl | 375~800 | ±0.004 ltl | 333~900 | ||||
WRF | J | ±1.5°C | -40~+375 | ±1.5°C | -40~+333 | ||
±0.004 ltl | 375~750 | ±0.004 ltl | 333~750 | ||||
WRC | T | ±1.5°C | -40~+125 | ±1°C | -40~+133 | ||
±0.004 ltl | 125~350 | ±0.0075 ltl | 133~350 |